No Logo
0
Filters & Suggestions

2 products found for Fire Sprinkler Head Products in KSA

Fire Sprinkler Head

Fire Sprinkler Head

  • Attribute Set : Fire Sprinkler Head_Fire Fighting Equipment
Noora Trading
Location : Riyadh
 
Fire Sprinkler Head

Foam Sprinkler Head

Fire Sprinkler Heads in KSA | Buy Automatic Fire Fighting Sprinkler Head

Fire sprinkler heads are essential components of automatic fire protection systems used in commercial buildings, warehouses, hospitals, hotels, industrial facilities, and residential projects across Saudi Arabia. Designed to activate automatically during a fire, they help control flames quickly while meeting NFPA, UL, FM, and Saudi Civil Defense requirements.

Suppliers across Riyadh, Jeddah, Dammam, Al Khobar, Jubail, and Yanbu offer pendent, upright, sidewall, concealed, recessed, conventional, ESFR, CMSA, quick response, and standard response fire sprinkler heads from leading brands including Tyco | Viking | Reliable | Globe | Senju | HD Fire | Rapidrop | Victaulic | Johnson Controls | NAFFCO.

Fire Sprinklers Head Supplier in KSA - Riyadh, Dammam, Jeddah

Noora Trading – Fire Fighting Equipment Supplier

Address: Noora Waqaiyan Sultan Al Dossary, Riyadh, Saudi Arabia

Phone: +966 11 214 6838

  • Supplies Fire Sprinkler Heads, control valves, fittings, and firefighting accessories.
  • Stock suitable for replacement parts and phased fire protection upgrades without replacing the complete sprinkler system.
  • Riyadh location offers a practical procurement option for projects requiring local availability and shorter delivery times.

Volcano House Contracting Company – Fire Sprinkler Head Supply & Fire Protection Installation

Address: Al Malaz, Riyadh, Saudi Arabia

Phone: +966 11 446 2175

  • Fire protection contractor offering Fire Sprinkler Heads alongside installation and maintenance.
  • Product portfolio includes fire pumps, suppression systems, valves, and firefighting equipment.
  • Single source for equipment supply, installation, testing, and periodic maintenance, reducing coordination between multiple vendors.

Lifeline Safety – UL Listed Fire Sprinkler Head Supplier in Saudi Arabia

Address: 3204 Omar Al Moukhtar, Al Amal, Riyadh 12644, Saudi Arabia

Phone: +966138346607

  • Stocks UL Listed and FM Approved Fire Sprinkler Heads for NFPA-compliant systems.
  • Product catalogue includes fire alarms, extinguishers, sprinkler accessories, and firefighting equipment.
  • Suitable for projects requiring internationally certified fire protection products specified by consultants and insurance providers.

Rakme Fire – Automatic Fire Sprinkler Head & Fire Fighting Equipment Supplier

Address: Al Othman Commercial Center 1st Floor , Room No : 15 A , Baladiya Street, Jeddah 21471, Jeddah, KSA

Phone: +966 12 661 4307

  • Supplies Automatic Fire Sprinkler Heads, fire pumps, control valves, hose reels, and suppression equipment.
  • Installation, testing, inspection, and maintenance available for fire protection systems.
  • One supplier for equipment procurement and system commissioning, helping maintain consistency across project stages.

Hopeway Fire Security – Fire Sprinkler Head & Life Safety Equipment Supplier

Address: Muhammad Bin Suleman District, Riyadh 12772, Saudi Arabia

Phone: +966 56 315 8697

  • Supplies Fire Sprinkler Heads, fire alarm systems, emergency lighting, and life safety products.
  • Product offering includes equipment for new construction and retrofit fire protection projects.
  • Buyers can source multiple life safety products through a single supplier, simplifying procurement for building fire safety packages.

REDA Safe – Tyco & Viking Fire Sprinkler Head Supplier in Saudi Arabia

Address: 2310 King Fahd Road, Al Rakah Al Janubiyah, Al Khobar 34227, Saudi Arabia

Phone: +920006023

  • Distributor of UL Listed and FM Approved Fire Sprinkler Heads from brands including Tyco and Viking.
  • Available models include the Tyco Quick Response Pendent Sprinkler (1/2" NPT, Chrome Finish) and Viking Upright Sprinkler (K-Factor 8, Brass Finish).
  • Product selection aligns with consultant-approved specifications for industrial, petrochemical, and infrastructure projects.

Falcon Power – Fire Sprinkler Head, Fire Pump & Fire Protection Equipment Supplier

Address: Palestine Street, Jeddah 23341, Saudi Arabia

Phone: +966 54 777 7503

  • Branch network across Jeddah, Madinah, and Khamis Mushait, with a central warehouse in Riyadh.
  • Supplies Fire Sprinkler Heads, fire pumps, valves, and firefighting equipment.
  • Regional branch network supports material availability and project deliveries across multiple Saudi cities.

First Advanced – Fire Sprinkler Head & Fire Protection System Supplier

Address: Prince Mamduh Bin Abdulaziz Street, As Sulimaniyah, Riyadh 12241, Saudi Arabia

Phone: +966 11 215 4059

  • Product range includes Fire Sprinkler Heads, suppression systems, fire alarm systems, and firefighting equipment.
  • Installation, testing, commissioning, retrofit, and maintenance for fire protection systems.
  • One supplier for both new-build fire protection systems and upgrades to existing facilities.

Gitco – Tyco Fire Sprinkler Head & Fire Protection Solutions Supplier

Address: King Abdulaziz Road, Al Khobar, Saudi Arabia (Head Office)

Phone: +966502145319

  • Supplies fire protection products from brands including Tyco and Notifier.
  • Hydraulic calculations, fire protection engineering, installation, testing, and commissioning available.
  • Combines equipment supply with hydraulic design and engineering services, reducing coordination between design consultants and product vendors.

Types of Sprinkler Head Available in KSA

Pendant Fire Sprinkler Heads – Best for Commercial Buildings, Offices & Residential Projects

Pendant fire sprinkler heads are the most widely installed automatic fire sprinkler heads in Saudi Arabia. They are suspended from ceiling-mounted pipework and use a convex deflector to distribute water in a 360° circular spray pattern, providing uniform coverage across the protected area.

  • Available in Quick Response and Standard Response models with K5.6, K8.0, and K11.2 discharge coefficients.
  • Standard temperature ratings include 57°C, 68°C, 79°C, 93°C, and 141°C.
  • Typical coverage area ranges from 9–21 m², depending on NFPA 13 design requirements.
  • Available in Brass, Chrome-Plated, White Polyester, Concealed, and Recessed finishes.
  • Most Fire Sprinkler Head Suppliers in KSA stock UL Listed and FM Approved Fire Sprinkler Heads with 1/2" or 3/4" NPT threaded connections and a maximum working pressure of 175 psi (12 bar).

Upright Fire Sprinkler Heads – Designed for Warehouses, Factories & Industrial Facilities

Upright fire sprinkler heads are mounted above exposed pipework and discharge water upward toward a concave deflector, allowing the spray to spread evenly over the protected area. They are specifically designed for buildings with exposed structural ceilings and high-bay storage environments.

  • Common K-Factors include K5.6, K8.0, K11.2, and K14 for higher water discharge.
  • Compatible with Wet Pipe, Dry Pipe, and ESFR fire sprinkler systems.
  • Available in Standard Response and Quick Response configurations.
  • Typical operating pressure ranges from 7–175 psi (0.5–12 bar).
  • Supplied in Brass, Chrome-Plated Brass, Stainless Steel, and corrosion-resistant coated finishes for demanding industrial environments.

Sidewall Fire Sprinkler Heads – Ideal for Corridors, Hotel Rooms & Compact Spaces

Sidewall fire sprinkler heads are installed horizontally on walls or structural beams instead of ceilings. Their half-deflector produces a 180° semi-circular water distribution pattern, making them an excellent solution where ceiling pipe installation is impractical or architectural finishes must be preserved.

  • Typical coverage area ranges from 12–18 m², depending on manufacturer listings and NFPA spacing requirements.
  • Available in Horizontal Sidewall and Vertical Sidewall configurations.
  • Common temperature ratings include 68°C, 79°C, and 93°C.
  • Offered with Quick Response, Standard Response, UL Listed, and FM Approved options.
  • Available in Chrome-Plated, White, and Concealed decorative finishes to complement modern interior designs.

Concealed & Recessed Fire Sprinkler Heads – Architectural Protection Without Visible Pipework

Concealed and recessed fire sprinkler heads combine high-performance fire protection with a clean architectural appearance. These sprinkler heads remain hidden behind a decorative cover plate or recessed escutcheon, which automatically releases when exposed to heat, allowing the sprinkler to activate without affecting room aesthetics.

  • Compatible with Quick Response and Standard Response sprinkler technologies.
  • Standard activation temperatures include 57°C, 68°C, 79°C, and 93°C.
  • Available with K5.6 and K8.0 discharge coefficients.
  • Decorative finish options include White, Chrome, Matte Black, and custom RAL colours.
  • Leading Fire Sprinkler Suppliers in Saudi Arabia offer UL Listed, FM Approved, and NFPA 13-compliant concealed sprinkler heads with 175 psi (12 bar) pressure ratings, making them suitable for projects requiring both fire safety compliance and premium interior aesthetics.

Temperature Ratings Of Fire Sprinkler Head

To prevent accidental activation, sprinkler heads are temperature-rated based on their surrounding environment.

The color of the glass bulb or the frame arms indicates its rating:

  • Red or Orange: 135°F to 155°F (57°C to 68°C) – Standard for residential and office environments.
  • Yellow or Green: 175°F to 200°F (79°C to 93°C) – Used in attics, boiler rooms, and warmer spaces.
  • Blue: 250°F to 286°F (121°C to 141°C) – For industrial environments.

Fire Sprinkler Head Products Offered by KSA Suppliers

Product Typical Specifications Key Features Popular Brands Estimated Price (SAR)
Fire Sprinkler Head K-Factor: 5.6, 8.0, 11.2 • Temperature Ratings: 68°C, 79°C, 93°C, 141°C • Connection: 1/2" & 3/4" NPT • Material: Brass, Chrome-Plated Brass • Certifications: UL Listed, FM Approved, NFPA 13, SASO Compatible Designed for light, ordinary and extra hazard occupancies. Compatible with wet pipe, dry pipe and pre-action systems. Selected based on hydraulic calculations, ceiling height and hazard classification. Suitable for commercial buildings, warehouses, hospitals and industrial facilities. Tyco, Viking, Reliable, Globe, Senju 18–75
Foam Sprinkler Head Foam-Water Discharge • AFFF Compatible • Brass/Stainless Steel • 1/2" & 3/4" NPT • UL/FM Listed Engineered for Class B flammable liquid fires. Used in oil & gas facilities, aircraft hangars, fuel depots and chemical plants. Requires compatible foam proportioning systems for effective suppression. Viking, Tyco, HD Fire 180–750
Recessed Sprinklers K5.6 & K8.0 • Concealed Escutcheon • Chrome Finish • UL/FM Listed • Ceiling Mounted Flush ceiling installation for hotels, hospitals, offices and luxury commercial interiors. Decorative cover plates improve aesthetics while allowing simple maintenance and replacement. Tyco, Viking, Reliable 35–120
HSW Extended Coverage Quick Response Sprinklers Horizontal Sidewall • Extended Coverage (up to 20 m²) • K5.6/K8.0 • Quick Response Bulb • UL/FM Approved Covers larger floor areas, reducing sprinkler quantity and installation costs. Frequently specified for schools, healthcare facilities, hotels and office buildings requiring faster occupant protection. Tyco, Viking, Globe 45–160
Vertical Sidewall Sprinklers Vertical Sidewall • K5.6/K8.0 • Brass or Chrome • 68°C–141°C • UL/FM Certified Designed for corridors, stairwells, parking garages and narrow spaces where ceiling installation is difficult. Provides directional water distribution while maintaining required coverage density. Viking, Reliable, Globe 35–110
Conventional Sprinklers Pendent/Upright Pattern • K5.6/K8.0 • Brass/Chrome • UL/FM Listed • Standard Spray Produces both upward and downward water distribution. Suitable for industrial facilities, retrofit projects and older fire sprinkler systems where existing piping layouts are retained. Tyco, Viking, HD Fire 20–80
Pendent, Upright & Recessed K-8 Sprinklers K-Factor 8.0 • 68°C–141°C • Brass/Chrome • UL/FM Listed • Standard Coverage Higher water discharge than K5.6 models for medium and high hazard occupancies. Commonly used in factories, warehouses, logistics centres and commercial buildings. Tyco, Viking, Reliable 30–95
Horizontal Sidewall K-8 Sprinklers Horizontal Sidewall • K8.0 • Quick or Standard Response • UL Listed • 1/2" NPT Ideal for hotels, apartments, dormitories and office spaces with limited ceiling piping. Higher flow capacity can reduce the total number of sprinklers required. Viking, Globe, Tyco 35–100
UL Listed Pendent Sprinklers UL Listed • K5.6/K8.0 • Standard & Quick Response • Brass/Chrome • 68°C–141°C Independently tested to UL standards and accepted for government, healthcare and commercial projects. Compatible with internationally approved fire protection systems. Tyco, Viking, Reliable 25–90
UL Listed Upright Sprinklers Upright Type • UL/FM Listed • K5.6/K8.0 • Brass/Chrome • Exposed Installation Preferred for warehouses and industrial buildings with exposed ceilings. Provides unobstructed spray distribution and allows easy inspection, testing and maintenance. Tyco, Globe, Senju 25–90
UL Listed Sidewall Sprinklers Horizontal Sidewall • UL Listed • Brass/Chrome • K5.6/K8.0 • Standard Coverage Installed where ceiling-mounted sprinklers are impractical. Suitable for corridors, hotel rooms, hospitals and residential developments while maintaining certified performance. Viking, Reliable, Tyco 30–95
Quick Response Fire Sprinkler Heads 3 mm Glass Bulb • K5.6/K8.0 • UL/FM Listed • 68°C–93°C Activates faster than standard response models to improve life safety. Recommended for schools, hotels, hospitals and residential buildings under NFPA 13 and NFPA 13R requirements. Tyco, Viking, Reliable 30–110
Standard Response Fire Sprinkler Heads 5 mm Glass Bulb • K5.6/K8.0 • UL/FM Listed • Brass/Chrome Designed primarily for property protection in factories, warehouses and commercial buildings. Cost-effective solution for standard fire protection system designs. Tyco, Globe, Senju 20–80
ESFR Fire Sprinkler Heads K14, K16.8, K22.4, K25.2 • Early Suppression Fast Response • FM Approved • High-Ceiling Protection Protects high-piled storage up to approximately 15–18 m (depending on listing). Can eliminate in-rack sprinklers in many warehouse applications, reducing installation complexity and maintenance costs. Tyco, Viking, Reliable 180–650
CMSA Fire Sprinkler Heads Control Mode Specific Application • K11.2–K25.2 • High Flow • UL/FM Certified Designed for palletized storage, manufacturing plants and distribution centres. Selected where CMSA protection provides the optimum hydraulic solution for stored commodities. Tyco, Viking 150–550
K-Factor Fire Sprinkler Heads Available in K5.6, K8.0, K11.2, K14, K16.8, K22.4 & K25.2 • UL/FM Listed • Multiple Temperature Ratings Enables engineers to match sprinkler discharge with hydraulic calculations. Larger K-Factors provide greater water flow at lower operating pressure for industrial and warehouse systems. Tyco, Viking, Reliable 20–250
Brass Fire Sprinkler Heads Solid Brass Body • 68°C–141°C • UL/FM Listed • Corrosion Resistant Durable and economical option for warehouses, factories and mechanical rooms. Natural brass finish offers long service life with minimal maintenance requirements. Tyco, Globe, Senju 18–70
Chrome Fire Sprinkler Heads Chrome-Plated Brass • Decorative Finish • UL/FM Certified • Corrosion Resistant Combines premium appearance with long-term corrosion protection. Frequently specified for hotels, airports, shopping malls, hospitals and modern commercial interiors where exposed sprinklers complement architectural finishes. Viking, Reliable, Tyco 22–85

Quick Response vs Standard Response Fire Sprinkler Heads – RTI, Activation Time & NFPA 13 Applications

  • Glass bulb size: Quick Response – 3 mm glass bulb. Standard Response – 5 mm glass bulb.
  • Response Time Index (RTI): Quick Response – ≤50 (m½·s½). Standard Response – ≥80 (m½·s½).
  • Best applications: Quick Response – hotels, hospitals, schools, residential buildings. Standard Response – warehouses, factories and industrial facilities.
  • NFPA recommendation: NFPA 13 typically requires Quick Response sprinklers in occupancies where life safety is the primary objective.
  • Typical K-Factor: Both are commonly available in K5.6, K8.0 and K11.2.
  • Temperature ratings: Standard options include 57°C, 68°C, 79°C, 93°C and 141°C.
  • Maximum working pressure: Up to 175 psi (12 bar) for most commercial models.
  • Available certifications: UL Listed, FM Approved and LPCB-certified models are widely supplied in Saudi Arabia.

Sidewall vs Pendant Fire Sprinkler Heads – Coverage Area, Installation Height & Room Layout

  • Installation location: Pendant sprinklers are ceiling mounted. Sidewall sprinklers are installed horizontally on walls.
  • Water distribution: Pendant heads provide 360° circular coverage, while sidewall models provide approximately 180° directional coverage.
  • Typical coverage area: Pendant – 9–21 m². Sidewall – 12–18 m², depending on manufacturer listings.
  • Best applications: Pendant – offices, warehouses, shopping malls. Sidewall – hotel rooms, corridors, apartments and healthcare facilities.
  • Pipe installation: Sidewall sprinklers reduce ceiling pipework and simplify installation in finished interiors.
  • Available finishes: Brass, Chrome-Plated, White Polyester and Concealed Cover Plate.
  • Certification: UL Listed and FM Approved models available from leading Fire Sprinkler Head Suppliers in Saudi Arabia.

Brass vs Chrome-Plated Fire Sprinkler Heads – Corrosion Resistance, Maintenance & Commercial Applications

Feature Brass Fire Sprinkler Heads Chrome-Plated Fire Sprinkler Heads
Corrosion Resistance Good durability for standard indoor industrial environments. Superior corrosion and stain resistance with a protective chrome finish.
Appearance Natural brass finish with an industrial look. Polished architectural finish suitable for visible installations.
Maintenance Requires periodic cleaning in exposed environments. Resists staining and requires less cleaning in public spaces.
Best Applications Warehouses, factories, mechanical rooms and industrial facilities. Hotels, hospitals, airports, office buildings, shopping malls and commercial interiors.
Available K-Factors K5.6, K8.0, K11.2 K5.6, K8.0, K11.2
Operating Pressure Up to 175 psi (12 bar) Up to 175 psi (12 bar)
Common Certifications UL Listed, FM Approved, NFPA 13 Compliant UL Listed, FM Approved, NFPA 13 Compliant

Frequently Asked Questions About Fire Sprinkler Head Suppliers in Saudi Arabia

Who are the leading Fire Sprinkler Head Suppliers in KSA?

Leading Fire Sprinkler Head Suppliers in KSA supply UL Listed and FM Approved Fire Sprinkler Heads for commercial, industrial, healthcare, hospitality, and infrastructure projects. Many suppliers offer products from international brands such as Tyco Fire Sprinkler Heads, Viking, Reliable, and other globally recognised manufacturers.

Where can I buy Fire Sprinkler Heads in Saudi Arabia?

You can buy Fire Sprinkler Heads in Saudi Arabia from authorised fire protection suppliers located in Riyadh, Jeddah, Dammam, Al Khobar, and other major cities. Many suppliers provide project quotations, technical support, installation services, and replacement components for new and existing fire protection systems.

What is the average Fire Sprinkler Head price in Saudi Arabia?

The Fire Sprinkler Head price depends on the sprinkler type, certification, K-Factor, finish, and manufacturer. Typical market prices include:

  • Standard Pendant Sprinkler Heads: SAR 18–45
  • Upright Fire Sprinkler Heads: SAR 20–50
  • Sidewall Fire Sprinkler Heads: SAR 30–80
  • Concealed Fire Sprinkler Heads: SAR 40–120
  • ESFR Fire Sprinkler Heads: SAR 180–650

Prices vary based on project quantity, certification requirements, and brand.

How do fire sprinklers work?

Many buyers ask, "How do fire sprinklers work?" Most Automatic Fire Sprinkler Heads operate using a heat-sensitive glass bulb or fusible link. When the surrounding temperature reaches the sprinkler's activation rating, the bulb breaks, allowing water to discharge directly over the fire. Each sprinkler activates independently, meaning only the sprinklers exposed to sufficient heat will operate.

What are the common Fire Sprinkler Head temperature ratings?

Standard Fire Sprinkler Head temperature ratings include:

  • 57°C (135°F) – Low-temperature environments
  • 68°C (155°F) – Offices, hotels, residential buildings
  • 79°C (175°F) – Commercial kitchens and warmer spaces
  • 93°C (200°F) – Industrial facilities
  • 141°C (286°F) and above – High-temperature industrial applications

The correct temperature rating depends on ambient conditions and the applicable fire protection design standard.

What is the difference between pendent and upright sprinkler heads?

The main difference between pendent and upright sprinkler heads is the installation position and spray pattern.

  • Pendent Fire Sprinkler Heads hang below ceiling pipework and distribute water downward in a circular pattern.
  • Upright Fire Sprinkler Heads are mounted above exposed pipework and discharge water upward toward a deflector before distributing it across the protected area.

Pendant models are commonly used in offices and commercial buildings, while upright sprinklers are preferred for warehouses and industrial facilities with exposed ceilings.

Which Fire Fighting Sprinkler is suitable for warehouses?

Warehouse fire protection systems commonly use ESFR, CMSA, or Upright Fire Fighting Sprinklers, depending on storage height, commodity type, and hydraulic calculations. High-bay warehouses often require FM Approved sprinkler heads with larger K-Factors such as K14, K16.8, or K22.4.

What certifications should I look for when purchasing Fire Sprinklers in Saudi Arabia?

For commercial and industrial projects, buyers generally specify:

  • UL Listed Fire Sprinkler Heads
  • FM Approved Fire Sprinkler Heads
  • NFPA 13 compliant products
  • Consultant-approved international brands

These certifications help ensure compatibility with project specifications and insurance requirements.

Are Tyco Fire Sprinkler Heads available in Saudi Arabia?

Yes. Tyco Fire Sprinkler Heads are available through several Fire Sprinkler Suppliers in Saudi Arabia, alongside other international brands such as Viking, Reliable, Globe, and Senju. Product availability depends on the supplier, project requirements, and stock levels.

How do I choose the right Fire Sprinkler Head supplier in KSA?

When selecting Fire Sprinkler Head Suppliers in KSA, compare:

  • Availability of UL Listed and FM Approved products
  • Stock of international brands such as Tyco Fire Sprinkler Heads
  • Technical support and hydraulic design assistance
  • Product range (sprinklers, valves, pumps, and accessories)
  • Delivery coverage across Riyadh, Jeddah, Dammam, and other regions
  • Installation, testing, and maintenance capabilities

Popular Categories