Surge Arrestor Suppliers in KSA | Type 1 & Type 2 SPDs, ESE Lightning Arresters, Zinc Oxide & Polymeric Surge Arresters
Find surge arrestor suppliers in KSA for Type 1 and Type 2 surge protection devices, modular surge arresters for distribution boards, PV surge protection, DTK-MRJ data line protectors, ESE lightning arresters, zinc oxide and polymeric surge arresters and high voltage surge arresters. Compare types, standards, discharge ratings, brands and indicative SAR prices, then contact surge protection device suppliers in KSA through FYIND with your network type, voltage and panel details to request a quotation.
Surge Arrestors in Saudi Arabia: Quick Summary
- What a surge arrestor does: it diverts lightning and switching surges to earth and limits the voltage that reaches cables, panels and equipment.
- Suppliers on this page: Lights of Power EST (Al Amal, Riyadh) for panel SPDs and lightning protection items; Eshraq Solar Energy (Majmaah, with a Riyadh office) and Zayel Solar (Riyadh) for PV and inverter surge protection.
- Main families: low-voltage SPDs (Type 1, Type 2, Type 3), PV DC SPDs, data and Ethernet SPDs, lightning arresters (ESE and conventional), and medium and high voltage zinc oxide (MOV) surge arresters.
- Key standards: IEC 61643-11 and UL 1449 for LV SPDs, IEC 61643-21 for data lines, IEC 61643-31 for PV, IEC 60099-4 and IEEE C62.11 for MV/HV arresters, IEC 62305 and NF C 17-102 for lightning protection.
- Indicative prices: Type 2 three-phase SPD SAR 250–2,500; Type 1+2 SPD SAR 900–6,000; ESE lightning arrester head SAR 3,000–25,000; MV polymeric arrester SAR 250–2,500 each.
Start Here
Match Your Job to the Right Surge Arrestor Before You Read Anything Else
| If Your Job Is… | You Need a… | Available From |
|---|---|---|
| Protect a building main panel fed by overhead lines or with a lightning rod | Type 1 or Type 1+2 SPD | Lights of Power EST (Riyadh): +966 11 402 2577 |
| Protect sub-distribution boards, HVAC and lighting panels | Type 2 Modular SPD | Lights of Power EST (Riyadh): +966 11 402 2577 |
| Protect solar PV strings and inverters | PV DC SPD (Type 2) and AC SPD | Eshraq Solar Energy (Majmaah & Riyadh): +966 57 058 2202 | Zayel Solar (Riyadh): +966 11 409 3353 |
| Protect a roof, tower or factory from direct lightning strikes | ESE or Conventional Lightning Arrester with Earthing | Lights of Power EST (Riyadh): +966 11 402 2577 |
| Protect CCTV, PoE and Ethernet links | DTK-MRJ / RJ45 Data Line SPD | Lights of Power EST (Riyadh): +966 11 402 2577 |
| Protect 11–33 kV overhead lines and transformers | Polymeric Zinc Oxide Surge Arrester | Lights of Power EST (Riyadh): +966 11 402 2577 (sourcing) | utility arrester makers’ KSA offices |
| Protect substations and transmission lines | High Voltage Station Class Surge Arrester | Lights of Power EST (Riyadh): +966 11 402 2577 (sourcing) | utility arrester makers’ KSA offices |
| Protect office PCs and electronics at the socket | Plug-In Surge Protector Strip (e.g. Belkin) | Lights of Power EST (Riyadh): +966 11 402 2577 |
Surge Arrestor Suppliers in KSA
Lights of Power EST: Surge Protection Device and Lightning Arrester Supplier in Riyadh
RIYADH · Al Amal · Central Riyadh electrical supply district · Panel SPDs, lightning arresters & electrical protection items
Phone: +966 11 402 2577 | Address: Al Amal, Riyadh, KSA
Surge Protection Products to Ask For
- Type 2 Modular Surge Protection Device: Standard: IEC 61643-11 | Rating: In 20 kA, Imax 40 kA typical | Poles: 1P+N or 3P+N | Mounting: DIN rail with plug-in modules and status window | Suitable For: Sub-distribution boards, HVAC panels and lighting panels.
- Type 1+2 Panel SPD: Standard: IEC 61643-11 Class I+II | Rating: Iimp 12.5–25 kA per pole | Networks: TN-C, TN-S, TT | Suitable For: Main distribution boards in buildings with lightning protection or overhead supply.
- Lightning Arrester and Earthing Accessories: Type: ESE air terminal or Franklin rod with down conductor, test clamp and earth pit | Standards: NF C 17-102 / IEC 62305 | Suitable For: Villas, towers, warehouses and factories.
- Data Line and Plug-In Surge Protectors: Type: RJ45 inline SPD (DTK-MRJ style) and plug-in surge strips | Suitable For: CCTV, PoE cameras, routers, PCs and office electronics.
Price Range
SAR 80–900 / Type 2 SPD | SAR 900–6,000 / Type 1+2 SPD | SAR 3,000–25,000 / ESE head | SAR 80–600 / RJ45 SPD
Why Choose Lights of Power EST
- Location Advantage: Based in Al Amal, close to Riyadh’s central electrical wholesale area around Batha, convenient for contractors collecting panel parts.
- Product Range: Listed on FYIND for surge arrestors; ask for Type 1, Type 2 and lightning protection items and the brands in stock.
- Coverage Area: Riyadh, with delivery to other cities on request.
- Contact: Call +966 11 402 2577 with network type (TN-S, TT), voltage, number of poles and kA rating.
- Industries Served: Electrical Contractors, Panel Builders, Building Maintenance and Facility Management.
- Note: Little public company information is online, so confirm brand, origin and IEC 61643 certificates when ordering.
Eshraq Solar Energy: PV Surge Protection and Solar Protection Device Supplier in Majmaah and Riyadh
AL MAJMAAH & RIYADH · Founded 2014 · Authorised agent for global solar brands · Panels, inverters, batteries & protection devices · 42 staff
Phone: +966 57 058 2202 | Riyadh Office: +966 50 519 5197 | Address: King Abdullah Road, Al Majmaah 15362; Omar Al-Mukhtar Street, Riyadh | Email: info@eshraq.com.sa
Surge Protection Products They Offer
- PV DC Surge Protection Device: Standard: IEC 61643-31 / EN 50539-11 | Voltage: 600–1,500 V DC | Rating: In 20 kA, Imax 40 kA typical | Brand: Suntree and similar solar protection brands | Suitable For: PV strings, combiner boxes and inverter DC inputs.
- AC Surge Protection Device for Inverter Output: Standard: IEC 61643-11 Type 2 | Poles: 1P+N or 3P+N | Suitable For: Inverter AC output and solar distribution boards.
- Circuit Breakers and Electrical Protection Systems: Type: DC and AC breakers, isolators, fuses and combiner box parts | Suitable For: On-grid, off-grid and hybrid solar systems.
- Cables and Connectors: Type: Solar DC cable and Staubli connectors | Suitable For: Safe PV string wiring.
Price Range
SAR 60–900 / PV DC SPD | SAR 150–1,500 / AC Type 2 SPD | Complete protection kits quote-based
Why Choose Eshraq Solar
- Company History: Founded in 2014 in Al Majmaah and installing systems since 2015, with an office on Omar Al-Mukhtar Street in Riyadh.
- Brand Range: JA Solar, GoodWe, Huawei, INVT, Voltronic, Hithium, NPP, Leader, Staubli and Suntree, a brand known for PV surge protectors and DC breakers.
- Supply Model: Distributor and installer with ready stock, technical guidance and complete supply packages for contractors and traders.
- Contact: Call +966 57 058 2202 or email info@eshraq.com.sa with PV string voltage and inverter model.
- Industries Served: Residential, Commercial, Industrial and Agricultural Solar Projects.
- Note: Best for surge protection for solar PV systems and inverters in Saudi Arabia.
Zayel Solar: Solar System Surge Protection Supplier and Installer in Riyadh
RIYADH · Shara Rail, opposite Bank Al Riyadh · Solar EPC & O&M · On-grid, off-grid, pumping & street lighting · Kingdom-wide service
Phone: +966 11 409 3353 | Address: Shara Rail, Opposite Bank Al Riyadh, Riyadh, KSA | Web: zayelsolar.com
Surge Protection Products They Offer
- PV Combiner Box with DC SPD: Type: String combiner with fuses, DC isolator and Type 2 DC SPD | Voltage: Up to 1,000–1,500 V DC | Suitable For: Rooftop and ground-mounted PV systems.
- Inverter AC Surge Protection: Type: Type 2 AC SPD in the inverter output board | Suitable For: On-grid and hybrid systems.
- Solar Pumping Surge Protection: Type: DC and AC SPDs for solar pump drives | Suitable For: Farms and remote wells exposed to lightning.
- Solar Street Lighting Protection: Type: Compact SPDs for pole-mounted controllers | Suitable For: Roads, parks and compounds.
Price Range
Supplied within solar system packages; SPD items SAR 60–1,500 depending on type and brand
Why Choose Zayel Solar
- Specialization: Integrated solar project supplier offering EPC and O&M, so surge protection is designed into the whole PV system.
- Product Range: Solar on-grid and off-grid systems, solar pumping, solar street lighting and battery storage, with Veichi listed among its inverter suppliers.
- Coverage Area: Riyadh base with installation and service across the Kingdom.
- Contact: Call +966 11 409 3353 with system size and location.
- Industries Served: Government, Hospitality, Construction, Utilities, Telecom, Agriculture and Industry.
- Note: Choose Zayel Solar when you want surge protection installed as part of a solar system.
Other Surge Protection Specialists Serving Saudi Arabia
- DEHN Middle East FZE: Regional subsidiary of the German surge and lightning protection maker DEHN, based in the UAE and serving GCC projects, including Saudi Arabia, through partners.
- ABB, Schneider Electric and Siemens: Supply branded Type 1 and Type 2 SPDs (ABB OVR, Schneider iPRD/iPF, Siemens 5SD7) through authorised electrical distributors in KSA.
- Hitachi Energy, Siemens Energy and ABB: Supply medium and high voltage zinc oxide surge arresters for utilities and substations; contact their Saudi offices for SEC and Aramco projects.
Surge Arrestor and SPD Products Available in KSA
| Product | Key Specification | Suitable For | Where to Ask |
|---|---|---|---|
| Type 2 Modular SPD | In 20 kA, Imax 40 kA, 1P+N / 3P+N | Sub-boards, HVAC | Lights of Power EST |
| Type 1+2 SPD | Iimp 12.5–25 kA/pole | Main boards | Lights of Power EST |
| PV DC SPD | 600–1,500 V DC, IEC 61643-31 | PV strings, inverters | Eshraq Solar, Zayel Solar |
| AC SPD for Inverters | Type 2, 230/400 V | Solar AC boards | Eshraq Solar, Zayel Solar |
| PV Combiner Box with SPD | Fuses, isolator, DC SPD | Rooftop and ground PV | Zayel Solar |
| ESE Lightning Arrester | NF C 17-102, ΔT 25–60 µs | Buildings, factories | Lights of Power EST |
| RJ45 / DTK-MRJ Data SPD | Cat5e/Cat6, PoE versions | CCTV, networks | Lights of Power EST |
| Plug-In Surge Protector | Socket strip with joule rating | Office electronics | Lights of Power EST |
| Polymeric Zinc Oxide Arrester | 11–33 kV distribution class | Overhead lines | Utility suppliers |
| HV Station Arrester | 66–380 kV | Substations | Utility suppliers |
Surge Arrestor Types And Surge Protection Devices In KSA
- Short Answer: Saudi buyers can source lightning arresters (ESE and conventional), low-voltage SPDs (Type 1, Type 2, Type 3), PV and data line SPDs, and medium and high voltage zinc oxide and polymeric surge arresters.
- Why the Type Matters: Each type protects a different point: lightning arresters catch direct strikes, Type 1 SPDs handle lightning current at the main board, Type 2 SPDs handle induced surges at sub-boards, and MV/HV arresters protect lines and transformers.
- How to Use This Section: Find the type that matches your installation, note what to check, then contact the supplier named under each type.
Lightning Surge Arrester For Building And Industrial Lightning Protection
- What It Is: A device or system that safely carries lightning current to earth, often combined with a Type 1 SPD at the main board.
- Problem It Solves: Prevents fires, structural damage and burnt equipment from lightning strikes on roofs, tanks, towers and factory buildings.
- Main Parts: Air terminal, down conductors, test joints, earth electrodes and equipotential bonding, plus SPDs on incoming services.
- Where It Is Used: Tall buildings, warehouses, plants, telecom towers, mosques, schools and remote sites.
- What to Check: Risk assessment to IEC 62305-2, protection level (I to IV), earth resistance target and bonding of metal services.
- Supplier Tip: Ask Lights of Power EST for arrester heads, earthing materials and matching Type 1 SPDs in one order.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
ESE Lightning Arrester For Early Streamer Emission Lightning Protection Systems
- What It Is: An Early Streamer Emission air terminal that launches an upward leader earlier than a plain rod, claimed to give a larger protection radius.
- Problem It Solves: Covers large roofs and open areas with one mast instead of many conventional rods.
- Key Rating: ΔT (advance time) of 25–60 µs, which sets the protection radius (Rp) in NF C 17-102 tables.
- Where It Is Used: Factories, compounds, stadiums, farms and residential towers in KSA.
- What to Check: NF C 17-102 (2011) test report, ΔT value, mast height, two down conductors and earth resistance.
- Important Note: ESE is not covered by IEC 62305; confirm which standard your consultant or Civil Defence approval requires.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Zinc Oxide Surge Arrester For Power Distribution And Substation Protection
- What It Is: A gapless surge arrester built from zinc oxide (metal oxide varistor) blocks that conducts heavily only above its rated voltage.
- Problem It Solves: Limits lightning and switching overvoltages on lines, transformers, cables and switchgear, preventing insulation failure.
- Key Ratings: Rated voltage (Ur), continuous operating voltage (Uc), nominal discharge current (5, 10 or 20 kA) and line discharge class.
- Where It Is Used: 11–33 kV distribution networks, ring main units, pole transformers and substations.
- Related Equipment: Zinc Oxide Surge Arrester, FUYI Surge Arresters and CT/PT Transformers are often bought together for substation and metering panels.
- What to Check: IEC 60099-4 type test report, system earthing (effectively or non-effectively earthed) and SEC specification.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 (sourcing) | utility arrester makers’ KSA offices
Polymeric Surge Arrestor For Outdoor Power Distribution Networks
- What It Is: A zinc oxide surge arrester housed in silicone rubber instead of porcelain.
- Problem It Solves: Lighter, shatter-proof and better in dust, sand and coastal pollution than porcelain arresters.
- Where It Is Used: Overhead lines, pole-mounted transformers and outdoor switchgear in Saudi desert and coastal areas.
- What to Check: Creepage distance for the pollution level (often heavy or very heavy in KSA), rated voltage and disconnector.
- Supplier Tip: Buy from makers with KEMA or CESI type tests and SEC approval.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 (sourcing) | utility arrester makers’ KSA offices
High Voltage Surge Arresters For Substations And Transmission Systems
- What It Is: Station class zinc oxide arresters for 66 kV to 380 kV systems, in porcelain or polymer housings.
- Problem It Solves: Protects power transformers, GIS and transmission lines from lightning and switching surges.
- Key Ratings: Line discharge class 2–5, energy capability, and pressure relief rating.
- Accessories: Surge counters and leakage current monitors to track arrester health.
- What to Check: SEC or Saudi Aramco specification, insulation coordination study and approved vendor list.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 (sourcing) | utility arrester makers’ KSA offices
Surge And Lightning Arrester For Industrial And Commercial Electrical Installations
- What It Is: A combined approach: external lightning protection on the building plus coordinated SPDs inside the electrical system.
- Problem It Solves: Stops both direct strike damage and surges travelling on power and data cables.
- Typical Package: Lightning arrester and earthing, Type 1+2 SPD at the MDB, Type 2 at sub-boards and data line SPDs.
- Where It Is Used: Malls, hospitals, factories, warehouses and office towers.
- What to Check: That the earthing for lightning protection and the electrical earth are bonded.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Modular Surge Arresters For Distribution Boards And Electrical Panels
- What It Is: DIN-rail SPDs with plug-in cartridges that can be replaced without rewiring.
- Problem It Solves: Lets maintenance staff swap a spent module quickly and see its status at a glance.
- Features: Visual status window (green/red), remote signalling contact and pole configurations 1P to 3P+N.
- Where It Is Used: MDBs, SMDBs, lighting panels, HVAC and control panels.
- What to Check: Uc (275 V or 320 V for 230 V systems), In and Imax, Up and back-up fuse or breaker size.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Surge Protection Device Type 2 For Low-Voltage Distribution Panels
- What It Is: An SPD tested with an 8/20 µs current wave, for induced and switching surges.
- Problem It Solves: Protects electronics, drives, LED lighting and controls from surges that enter through cables.
- Typical Ratings: In 20 kA, Imax 40 kA, Up 1.2–1.5 kV.
- Where It Is Installed: Sub-distribution boards and close to sensitive equipment, within about 10 m of the load where possible.
- What to Check: Network type, short cable leads to earth and a correct back-up protective device.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Type 1 And Type 2 Panel SPDs For TN, TT And IT Power Networks
- TN-S and TN-C-S: Common in Saudi buildings; SPDs connect line-to-PE and N-to-PE (3+1 or 4+0 configuration).
- TT Networks: Use 3+1 configuration (L-N SPDs plus an N-PE spark gap) so earth faults do not stress the SPD.
- IT Networks: Industrial and hospital IT systems need SPDs rated for line-to-line voltage (Uc around 440–690 V).
- Combined Type 1+2: One device at the main board handles lightning current and gives a low protection level.
- What to Check: Confirm the network with your electrical drawings before ordering, because a wrong SPD can fail on an earth fault.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
DTK-MRJ Surge Protection Devices For Ethernet And Data Communication Lines
- What It Is: The DITEK DTK-MRJ series of inline RJ45 surge protectors, including PoE versions such as DTK-MRJPOE.
- Problem It Solves: Protects network switches, IP cameras and access control from surges on outdoor or long Ethernet runs.
- Where It Is Used: CCTV poles, gate barriers, outdoor Wi-Fi and building automation networks.
- Standards: Buyers search for DTK-MRJ devices meeting IEC 61643 and UL 1449 standards; data-line protectors are usually tested to UL 497B and IEC 61643-21, so ask for the exact certificate.
- What to Check: Cat5e or Cat6, PoE class, shielded or unshielded and a solid earth connection.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
FUYI Surge Arresters For Electrical Power System Protection
- What It Is: FUYI is a brand of zinc oxide and polymeric surge arresters offered by Asian suppliers for distribution networks.
- Where It Is Used: Distribution lines, transformers and switchgear on lower-budget or private network projects.
- What to Check: Rated voltage, discharge current, IEC 60099-4 type test report, independent lab certificates and SEC acceptance before buying.
- Buying Tip: For SEC-connected networks, use only approved vendor brands; confirm FUYI acceptance with the utility first.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 (sourcing) | utility arrester makers’ KSA offices
IEEE 386 Bushing Well For Medium-Voltage Separable Connector Systems
- What It Is: A standard bushing socket on transformers and switchgear that accepts IEEE 386 inserts, elbows and elbow surge arresters.
- Problem It Solves: Gives dead-front, touch-safe cable connections and lets you plug in an elbow arrester at cable ends.
- Where It Is Used: Pad-mounted transformers, underground distribution and ring main units built to American standards (15, 25 and 35 kV class).
- Ratings: 200 A load-break and 600 A dead-break interfaces.
- What to Check: Voltage class, 200 A or 600 A interface and matching brand of insert and elbow.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 (sourcing) | utility arrester makers’ KSA offices
Surge Arrestor Applications In Saudi Arabia
- Short Answer: Surge protection is used in buildings, industry, HVAC, IT, solar, data centres, telecom towers and utility networks across the Kingdom.
- Why It Matters in KSA: Summer thunderstorms in the southwest and Eastern Province, long overhead lines, frequent switching and large HVAC loads make surges common.
Surge Protection Device In KSA For Commercial Buildings And Industrial Electrical Panels
- Need: Protect MDBs, SMDBs, drives, PLCs and LED lighting.
- Typical Setup: Type 1+2 SPD at the MDB and Type 2 at every SMDB.
- What to Check: Network type, fault level and back-up fuse.
- Benefit: Fewer burnt drives, control cards and lighting drivers.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Power Surge Protector In Jeddah For Commercial And Industrial Equipment
- Need: Coastal humidity and grid switching cause surges that damage equipment.
- Typical Setup: Type 2 SPDs at panels and plug-in surge protectors for sensitive devices.
- Sourcing: Riyadh suppliers on this page deliver to Jeddah; confirm lead time.
- Tip: Use SPDs with remote signalling for unattended sites.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 | Eshraq Solar Energy (Majmaah & Riyadh): +966 57 058 2202
Lightning Arrester In Riyadh For Building And Industrial Lightning Protection
- Need: Tall buildings, warehouses and towers need lightning protection approved for Civil Defence.
- Typical Setup: ESE or conventional air terminal, down conductors and earth pits with test clamps.
- What to Check: Earth resistance (often below 10 ohms) and annual testing.
- Supplier: Lights of Power EST in Al Amal, Riyadh.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Surge Arrester In Dammam For Industrial Power Distribution Systems
- Need: Plants and petrochemical sites have long cables, large motors and frequent switching.
- Typical Setup: MV surge arresters at transformers, Type 1+2 SPDs at LV boards and SPDs on control circuits.
- What to Check: Saudi Aramco or client specifications and approved brands.
- Sourcing: Ask Riyadh suppliers for delivery, or utility arrester makers’ Eastern Province offices.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
HVAC Surge Protector In Jubail For Air Conditioning And Building Automation Equipment
- Need: Chillers, VRF units, AHUs and BMS controllers are expensive and sensitive to surges.
- Typical Setup: Type 2 SPD in each HVAC panel and data SPDs on BMS lines.
- Benefit: Avoids compressor and inverter board failures after storms or grid switching.
- What to Check: Panel voltage and phase, and space on the DIN rail.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Belkin Surge Protector In Al Khobar For Office Electronics And IT Equipment
- What It Is: Belkin and similar plug-in surge protector strips with joule ratings and protected sockets.
- Where It Is Used: Office PCs, monitors, printers, TVs and home office equipment.
- Limits: Plug-in strips are Type 3 point-of-use protection; they work best with Type 2 SPDs in the panel.
- What to Check: Joule rating, number of sockets, UK-style plug (BS 1363) and USB charging.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Surge Protection For Solar PV Systems And Inverters In Saudi Arabia
- Need: PV arrays on roofs and open land are exposed to lightning and long DC cables pick up surges.
- Typical Setup: DC SPD (Type 2, IEC 61643-31) in combiner boxes and at the inverter DC input, AC Type 2 SPD at inverter output.
- What to Check: Maximum PV voltage (Ucpv 600–1,500 V DC), Y-connection SPD and earthing of frames.
- Suppliers: Eshraq Solar for components; Zayel Solar for installed systems.
Available From: Eshraq Solar Energy (Majmaah & Riyadh): +966 57 058 2202 | Zayel Solar (Riyadh): +966 11 409 3353
Surge Protection For Data Centres, Telecom Towers And Control Panels In KSA
- Data Centres: Type 1+2 at the main incomer, Type 2 at UPS and PDU boards, and data line SPDs.
- Telecom Towers: Lightning protection, Type 1 SPD on AC, DC SPDs on rectifiers and coaxial protectors on feeders.
- Control Panels: Type 2 SPDs on 230 V supply and signal SPDs on 4–20 mA and RS-485 lines.
- What to Check: Coordinated design and a low-impedance earthing system.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 | Zayel Solar (Riyadh): +966 11 409 3353
Find Surge Arrestor and Surge protection Device Suppliers In KSA
- Short Answer: Match the supplier to the voltage level: LV panel and data SPDs from electrical suppliers, PV SPDs from solar suppliers, and MV/HV arresters from utility-approved manufacturers.
- Use FYIND: Search FYIND for surge protection device suppliers in KSA by product and city, then send the same specification to two or three suppliers.
Surge Arrestor Suppliers In KSA For Industrial And Commercial Electrical Projects
- Who to Ask: Lights of Power EST in Riyadh for panel SPDs and lightning protection items.
- What to Send: Single-line diagram, network type, MDB rating and number of boards.
- What to Expect: A list of SPDs per board, with brand, ratings and price.
- Tip: Ask for datasheets and IEC 61643-11 certificates for consultant approval.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Surge Protection Device Suppliers In Saudi Arabia For Type 1 And Type 2 SPDs
- Type 1: For main boards with lightning protection or overhead supply.
- Type 2: For sub-boards and equipment panels.
- Who to Ask: Lights of Power EST for building SPDs; Eshraq Solar for solar Type 2 SPDs.
- Check: Brand authorisation and stock of replacement modules.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 | Eshraq Solar Energy (Majmaah & Riyadh): +966 57 058 2202
High Voltage Surge Arrestor Suppliers In KSA For Substations And Power Networks
- Who Supplies: Utility-approved manufacturers such as Hitachi Energy, Siemens Energy and ABB, through their Saudi offices and approved agents.
- Requirements: SEC or Saudi Aramco approved vendor status, type test reports and factory acceptance tests.
- FYIND Route: Ask Lights of Power EST to source smaller orders, or contact manufacturers directly for projects.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 (sourcing) | utility arrester makers’ KSA offices
Lightning Surge Arrester Suppliers In Saudi Arabia For Building Protection Systems
- Who to Ask: Lights of Power EST for ESE heads, rods, conductors and earthing.
- Design: Ask for a risk assessment and layout drawing, not only the arrester head.
- Approvals: Confirm Civil Defence and consultant requirements before buying.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Modular Surge Arrestor Suppliers In KSA For Distribution Boards
- Who to Ask: Lights of Power EST for modular Type 2 and Type 1+2 SPDs.
- Spares: Ask about replacement cartridges for the same model.
- Brands: Compare ABB, Schneider, DEHN, OBO, Phoenix Contact and Chinese brands on ratings and price.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Zinc Oxide Surge Arrester Suppliers In Saudi Arabia For Medium- And High-Voltage Applications
- Distribution Class: 11–33 kV polymeric arresters for overhead lines and transformers.
- Station Class: 66–380 kV arresters for substations.
- Who to Ask: Utility arrester manufacturers’ KSA offices; Lights of Power EST for sourcing small quantities.
- Check: IEC 60099-4 type tests and utility approval.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 (sourcing) | utility arrester makers’ KSA offices
Surge Protection Features And Working Principle
Surge Protection Device Working Principle For Transient Overvoltage Protection
- Normal Operation: At normal voltage the SPD has very high resistance and draws almost no current.
- During a Surge: When voltage rises above its threshold, the MOV or spark gap conducts in nanoseconds and diverts surge current to earth.
- After the Surge: It returns to high resistance automatically, ready for the next event.
- End of Life: A thermal disconnector separates a worn MOV and the indicator turns red.
- Key Point: An SPD only works with a good earth and short connecting leads.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Key Features Of Surge Protection In Saudi Arabia
- High Temperature Rating: Choose SPDs rated for enclosure temperatures above 50°C common in Saudi summers.
- Replaceable Modules: Plug-in cartridges cut downtime.
- Remote Signalling: Dry contacts alert BMS or SCADA when a module fails.
- Low Protection Level: Lower Up gives better equipment protection.
- Certification: IEC 61643 and, for US-spec projects, UL 1449.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Surge Arrestor Discharge Current And Voltage Protection Level
- In (Nominal Discharge Current): The 8/20 µs current the SPD can handle repeatedly, typically 20 kA for Type 2.
- Imax (Maximum Discharge Current): The highest 8/20 µs current it survives once, typically 40 kA.
- Iimp (Impulse Current): 10/350 µs lightning current for Type 1 SPDs, typically 12.5–25 kA per pole.
- Up (Voltage Protection Level): The residual voltage let through; lower is better, typically 1.2–2.5 kV.
- Uc (Maximum Continuous Voltage): Must exceed the network voltage, e.g. 275 V or 320 V for 230 V systems.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Surge Protection Device With Replaceable Modules And Status Indicators
- How It Works: Each pole has a plug-in module on a fixed base wired into the panel.
- Status Indicator: Green means healthy; red means replace.
- Benefit: Replace a module in minutes without disconnecting cables.
- Tip: Keep a spare module for each SPD model on critical sites.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Surge Protection For TN, TT And IT Power Networks
- TN Systems: Most Saudi buildings use TN-S or TN-C-S; use 4+0 or 3+1 SPD configurations.
- TT Systems: Use 3+1 with an N-PE spark gap.
- IT Systems: Use SPDs with Uc rated for line-to-line voltage.
- Why It Matters: A wrong configuration can cause SPD failure or fire during an earth fault.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Surge Protection Coordination For Main Boards And Distribution Panels
- Layered Protection: Type 1 at the main board, Type 2 at sub-boards and Type 3 near sensitive equipment.
- Coordination: Use SPDs from the same family or follow the maker’s cable length rules so energy is shared correctly.
- Cable Lengths: Keep SPD leads under 0.5 m total to keep let-through voltage low.
- Back-Up Protection: Fit the fuse or breaker size the SPD datasheet specifies.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577
Surge Arrestor Certifications, Compliance And Standards
- Short Answer: LV SPDs follow IEC 61643-11 (or UL 1449 for US-spec projects), data SPDs IEC 61643-21, PV SPDs IEC 61643-31, and MV/HV arresters IEC 60099-4 or IEEE C62.11.
- Why It Matters: Consultants, Civil Defence, SEC and Saudi Aramco reject products without the right test reports.
| Standard | What It Covers | Typical Product |
|---|---|---|
| IEC 61643-11 / EN 61643-11 | Low-voltage power SPDs, Type 1, 2 and 3 | Panel SPDs |
| UL 1449 (5th Ed.) | US safety standard for SPDs | SPDs on US-spec projects |
| IEC 61643-21 / UL 497B | Telecom and data line protectors | DTK-MRJ, RJ45 SPDs |
| IEC 61643-31 / EN 50539-11 | SPDs for PV DC installations | PV DC SPDs |
| IEC 60099-4 / IEEE C62.11 | Metal oxide surge arresters for AC systems | Zinc oxide MV/HV arresters |
| IEC 62305 (1–4) | Lightning protection risk, design and earthing | Lightning protection systems |
| NF C 17-102 (2011) | ESE lightning protection systems | ESE arresters |
| IEEE 386 | Separable insulated connector systems | Bushing wells, elbow arresters |
| SASO / Saudi Building Code (SBC 401) | Saudi product conformity and electrical code | All products sold in KSA |
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 | Eshraq Solar Energy (Majmaah & Riyadh): +966 57 058 2202
Which Surge Protection Brands Are Available in Saudi Arabia?
| Brand | Origin | Range | Where to Ask |
|---|---|---|---|
| DEHN | Germany | Type 1, 2, 3 SPDs, data SPDs, lightning protection | Lights of Power EST |
| OBO Bettermann | Germany | SPDs, PV SPDs, lightning protection and earthing | Lights of Power EST |
| ABB (OVR) | Switzerland | Type 1, 2 and PV SPDs; MV arresters | Lights of Power EST |
| Schneider Electric (iPRD / iPF) | France | Modular Type 1 and Type 2 SPDs | Lights of Power EST |
| Phoenix Contact | Germany | Power, PV and signal SPDs | Lights of Power EST |
| Suntree | China | PV DC SPDs, DC breakers and isolators | Eshraq Solar |
| DITEK | USA | DTK-MRJ data and PoE SPDs, panel SPDs | Lights of Power EST |
| Indelec / Franklin France / Helita | France | ESE lightning arresters | Lights of Power EST |
| Hitachi Energy / Siemens Energy | Switzerland / Germany | MV and HV zinc oxide arresters | Utility suppliers |
| FUYI | Asia | Zinc oxide and polymeric arresters | Ask suppliers |
| Belkin | USA | Plug-in surge protector strips | Lights of Power EST |
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 | Eshraq Solar Energy (Majmaah & Riyadh): +966 57 058 2202
Surge Protection Device Price In KSA
- Short Answer: Type 2 SPDs cost about SAR 80–2,500, Type 1+2 SPDs SAR 900–6,000, PV DC SPDs SAR 60–900 and ESE arrester heads SAR 3,000–25,000.
- What Affects Price: Type, kA rating, poles, brand, certification and remote signalling.
| Product | Economy / Generic (SAR) | Branded / Premium (SAR) | Where to Ask |
|---|---|---|---|
| Type 2 SPD, 1P+N, 40 kA | 80–250 | 250–900 | Lights of Power EST |
| Type 2 SPD, 3P+N, 40 kA | 250–900 | 800–2,500 | Lights of Power EST |
| Type 1+2 SPD, 3P+N, 12.5–25 kA/pole | 900–2,500 | 2,000–6,000 | Lights of Power EST |
| Replacement SPD module | 40–200 | 150–600 | Lights of Power EST |
| PV DC SPD, 600–1,500 V | 60–300 | 250–900 | Eshraq Solar, Zayel Solar |
| PV combiner box with SPD | 300–1,000 | 800–3,000 | Zayel Solar |
| RJ45 / DTK-MRJ data SPD | 80–250 | 200–600 | Lights of Power EST |
| Plug-in surge protector (e.g. Belkin) | 60–150 | 120–400 | Lights of Power EST |
| ESE lightning arrester head | 3,000–9,000 | 7,000–25,000 | Lights of Power EST |
| Complete building lightning protection (installed) | 15,000–40,000 | 30,000–100,000+ | Lights of Power EST |
| MV polymeric zinc oxide arrester (11–33 kV) | 250–900 | 700–2,500 | Utility suppliers |
| IEEE 386 elbow arrester / bushing well insert | 300–1,200 | 900–3,000 | Utility suppliers |
| HV station arrester (132–380 kV) | Quote-based | 15,000–150,000+ | Utility suppliers |
- Note: Prices are indicative estimates; request a written quote from FYIND suppliers.
Available From: Lights of Power EST (Riyadh): +966 11 402 2577 | Eshraq Solar Energy (Majmaah & Riyadh): +966 57 058 2202 | Zayel Solar (Riyadh): +966 11 409 3353
Frequently Asked Questions About Surge Arrestors
What Is A Type 2 Surge Arrestor?
- Definition: A Type 2 SPD protects against induced and switching surges, tested with an 8/20 µs current wave.
- Where Used: Sub-distribution boards and equipment panels.
- Typical Rating: In 20 kA, Imax 40 kA.
Which Company Surge Protector Is Best?
- Panel SPDs: DEHN, OBO Bettermann, ABB, Schneider Electric and Phoenix Contact are widely trusted.
- Solar: Suntree is common for PV DC SPDs in budget systems.
- Plug-In: Belkin is a popular choice for office electronics.
- Best Choice: The best surge protector matches your network type, ratings and certification.
What Is The Difference Between A Surge Arrestor And A Lightning Arrester?
- Lightning Arrester: Catches direct lightning strikes on the building and sends them to earth.
- Surge Arrestor / SPD: Limits overvoltage on electrical and data cables.
- Together: Most buildings need both for full protection.
How Does A Surge Protection Device Work?
- Normally: It stays inactive at normal voltage.
- During a Surge: It conducts in nanoseconds and diverts surge current to earth.
- After: It resets automatically; worn modules show a red indicator.
Where Should A Type 2 Surge Protection Device Be Installed?
- Location: In sub-distribution boards and panels feeding sensitive equipment.
- Wiring: With the shortest possible leads to the earth bar.
- With Type 1: Downstream of a Type 1 SPD at the main board where lightning risk exists.
Can Surge Protection Devices Be Used In TN, TT And IT Networks?
- Yes: SPDs are made for all three earthing systems; the configuration must match.
- TN Networks: Use 4+0 (TN-C) or 3+1 / 4+0 (TN-S) configurations.
- TT Networks: Use 3+1 with an N-PE spark gap.
- IT Networks: Use SPDs with Uc rated for line-to-line voltage.
Are DTK-MRJ Surge Protection Devices Compliant With IEC 61643 And UL 1449?
- Product: DTK-MRJ is DITEK’s RJ45 inline surge protector family, including PoE models.
- Standards: Data protectors are generally tested to data-line standards such as UL 497B and IEC 61643-21; UL 1449 applies to power SPDs.
- What to Do: Ask the supplier for the certificate that applies to the exact part number before approval.
What Is A Zinc Oxide Surge Arrester Used For?
- Use: Protecting medium and high voltage lines, transformers, cables and substations from lightning and switching overvoltages.
- Why Zinc Oxide: Zinc oxide blocks conduct sharply above rated voltage and need no spark gaps.
- Housing: Polymeric housings suit dusty and coastal Saudi conditions.
What Is An ESE Lightning Arrester?
- Definition: An Early Streamer Emission air terminal designed to NF C 17-102 to cover a wide radius from one mast.
- Key Rating: Advance time ΔT, usually 25–60 µs.
- Note: Check whether your project accepts NF C 17-102 or requires IEC 62305.
What Is An IEEE 386 Bushing Well Used For?
- Use: Connecting load-break inserts, elbows and elbow surge arresters on MV transformers and switchgear.
- Ratings: 15, 25 and 35 kV classes with 200 A load-break interfaces.
- Benefit: Dead-front, touch-safe connections and easy arrester fitting at cable ends.
What Is The Difference Between Type 1 And Type 2 Panel SPDs?
- Type 1: Handles direct lightning current (10/350 µs) at the main board.
- Type 2: Handles induced surges (8/20 µs) at sub-boards.
- When You Need Type 1: When the building has a lightning protection system or an overhead supply.
- Combined: Type 1+2 devices do both jobs at the main board.
How Often Should A Surge Protection Device Be Inspected Or Replaced?
- Inspection: Check status indicators monthly and after every storm, and test during annual maintenance.
- Replacement: Replace the module when the indicator turns red or after a major surge event.
- Typical Life: Often 5–10 years in normal conditions, shorter where surges are frequent.





